Supported drives/system per tray capacity:raw,
unformatted
73GB Disk drives
12 x 73GB = 876GB
146GB Disk drives
12 x 146GB = 1.75TB
300GB Disk drives
12 x 300GB = 3.6TB
400GB Disk drives
12 x 400GB = 4.8TB
450GB Disk drives
12 x 450GB = 5.4TB
500GB Disk drives
12 x 500GB = 6.0TB
750GB Disk drives
12 × 750GB = 9TB
1TB Disk Drives
12 x 1TB = 12.0TB
Drive Specifications
Form factor: 3.5 in.,
low-profile Interface: Dual-ported SAS
Note 1: Dynamic capacity expansion of 5 to 36
drives - 365GB to 10.8TB. Note 2: Up to two expansion trays are supported.
Note 3: Drive depopulation scales from 5 to 12 disk drives per tray.
Interfaces
Host interfaces/link speeds
Two to four 4 Gbps FC host ports per controller tray, up to 1GB cache per
controller
Other interfaces
Up to two 10/100 Base-T Ethernet
Serial
Up to two nine-pin RS-232 ports per dual controller tray
Environment
Heat Output
460 watts (1,571 BTU/hr.)
AC Power
515 watts (+5V @ 19A/+12V @ 35A)
Operating Temperature
10° C to 40° C (50° F to 104° F), without battery;
10° C to 35° C (50° F to 95° F), with battery
Operating Relative Humidity
20% to 80% relative humidity, noncondensing
Nonoperating Temperature
-10° C to 50° C (14° F to 122° F), without
battery; -10° C to 45° C (14° F to 113° F), with battery
Nonoperating Relative Humidity
10% to 90% relative humidity, noncondensing, max
dew point is 26° C (79° F), 10 percent per hour gradient.
Operating Altitude
68.3 kPa (3,200 m), 40° C, four-hour dwell
Nonoperating Altitude
18.8 kPa (12,200 m), 0° C, four-hour dwell
Shock
33 Gs, 11msec, half-sine, three shocks per
direction, all six directions
Vibration
All three axes:1.2 Gs, five to 500 Hz, swept-sine,
five sweep cycles, one octave per minute
Dimensions and
Weights
Height
86.1 mm (3.39 in)
Width
448.6 mm (17.66 in)
Depth
540 mm (21.26 in)
Weight (maximum)
27.01 kg (59.55 lb) with 12 disks
Regulations
Note: Meets or exceeds the following
requirements.
Safety and Emissions
FCC Class A VCCI Class A, EN55022 Class A, EN
55024 UL BSM
Rack
Mounting
Rack mountable in 19 inch-wide rack
Clearance
and Service Access
Front
38 cm (15 in) for service access 15 cm (6 in)
for cooling
Rear
38 cm (15 in) for service access 15 cm (6 in)
for cooling
Airflow for cooling is from front to rear.